Lower OPEX
Power produced on your own roof carries no market swings or network fees for that part of your consumption.
Plants for halls, hotels, shops, offices and farms, sized to your consumption — without oversizing. A clear payback, IRR and lower operating costs from the first month of operation.
In short: Brant Energy (Trogir) designs and builds turnkey solar plants for businesses, hotels, shops and farms across Croatia — from consumption analysis and a feasibility study to the grid procedure and commissioning. For a business using about 120,000 kWh a year this is typically a plant of about 68 kWp, an investment of about €49,000 excl. VAT and a payback of about 5 years. An engineer replies within 24 hours.
Power produced on your own roof carries no market swings or network fees for that part of your consumption.
We match the plant to consumption, because surplus sent to the grid is worth far less than power you use yourself.
Lower CO₂ emissions and a measurable share of renewable energy — data that customers, banks and partners ask for.
One contact person, clear deadlines and documentation prepared for your accounting.
Enter your activity, annual consumption and available area. You get a recommended size without oversizing, the investment, annual savings, payback and IRR.
Indicative results from our business calculator for a site in Split-Dalmatia County, excl. VAT. Your result depends on consumption, roof and how much power you use during the day.
Savings shown per year. Investment excl. VAT (reverse charge). Rebate and grant depend on HBOR and Modernisation Fund terms and are shown for illustration.
Indicative figures for a south-facing roof in Split-Dalmatia County, with panels of about 465 W. We always choose the size from your actual consumption, without oversizing.
| Plant size | Indicative investment (excl. VAT) | Panels | Roof area | Annual production | For annual consumption of about | Indicative annual savings | Your building |
|---|---|---|---|---|---|---|---|
| 30 kW | about €23,400 | 65 | about 145 m² | about 43,800 kWh | 56,000 kWh | about €4,800 | Study → |
| 40 kW | about €31,000 | 86 | about 190 m² | about 58,000 kWh | 74,000 kWh | about €6,300 | Study → |
| 50 kW | about €37,200 | 108 | about 240 m² | about 72,800 kWh | 93,000 kWh | about €7,900 | Study → |
| 70 kW | about €50,600 | 151 | about 330 m² | about 101,800 kWh | 130,000 kWh | about €11,100 | Study → |
| 80 kW | about €57,700 | 172 | about 380 m² | about 116,000 kWh | 148,000 kWh | about €12,600 | Study → |
| 90 kW | about €65,000 | 194 | about 430 m² | about 130,800 kWh | 167,000 kWh | about €14,300 | Study → |
| 100 kW | about €72,100 | 215 | about 475 m² | about 145,000 kWh | 185,000 kWh | about €15,800 | Study → |
| 500 kW | on request, based on a study | 1,075 | about 2,370 m² | about 725,000 kWh | 925,000 kWh | about €79,000 | Enquiry → |
Savings assume the business uses about a third of the electricity produced directly during the day and exports the rest to the grid. The investment is indicative, excluding VAT (reverse charge) and without grants. A flat roof with an east–west layout produces about 10 % less. The business solar estimate shows the investment and payback for your building.
The most common choice for farms, wineries, smaller hotels, shops and office buildings using about 50,000 to 90,000 kWh a year. They need about 145 to 240 m² of roof; we check the roof’s load capacity before the offer.
For production sites, cold stores, larger hotels and retail buildings using about 130,000 to 190,000 kWh a year. They need about 330 to 475 m² of roof, most often the metal roof of a hall.
For large production sites, logistics centres and halls with about 2,400 m² of roof, or for a ground-mounted plant. At this size we determine the capacity and feasibility from your metering data (load profile), and the grid connection procedure is more extensive. Contact us for a feasibility study — the online calculator covers plants up to 150 kWp.
Businesses on Croatia's red low-voltage tariff and customers connected at medium voltage pay not only for energy but also for billed peak active power — the highest 15-minute average load in the month. It takes just one moment when compressors, ovens or air conditioning start together, and that peak sets the demand charge for the whole billing period.
A solar plant reduces the load drawn from the grid while it produces, softening daytime peaks — especially in summer, when air conditioning runs hardest. More reliable results come from combining the plant with a battery and load management: the battery discharges exactly at peak moments, and the system delays or staggers the start of large loads.
We estimate what this is worth for your site from 15-minute metering data and include it with the offer.
The best payback goes to sites that use most of their power during the day — when the plant produces.
Machines, compressors and cooling run during the day, so much of the output is used directly on site.
Summer air conditioning and hot water coincide with peak production. Guests increasingly expect an EV charger too.
Lighting and display fridges run all day, and flat roofs are ideal for a plant.
Irrigation, cold storage and dryers — with the option of a hybrid system for remote plots.
IT and air conditioning during working hours — predictable consumption and a simple calculation.
Fleet chargers alongside the plant: vehicles charge on your own energy, with per-vehicle monitoring.
A business project starts with numbers, not a sales pitch.
15-minute load curves and bills for the last 12 months.
Optimal size, investment, cash flow, payback and IRR.
Main design, roof structural check and the full grid procedure.
Mounting planned around your operations, testing and a trial run.
Remote monitoring of the plant and data for ESG reports.
Manufacturer's product warranty.
Guaranteed panel output power.
Inverter manufacturer's warranty.
On Brant Energy's mounting and electrical work.
It depends on consumption, electricity prices and how much of the produced energy you use during the day. The calculator gives an estimated payback and IRR, and the feasibility study is based on your actual metering data.
Surplus power fed into the grid is worth far less than power you use yourself. That is why we size the plant to your consumption — it gives the shortest payback and the smallest investment.
Reverse-charge VAT applies to construction work between VAT-registered businesses in Croatia. Prices in the business calculator are shown excluding VAT.
Yes, if peaks coincide with production; with a battery and load management the effect is larger and more reliable. We estimate it from 15-minute metering data.
The calculator covers plants up to about 150 kWp. For larger projects we prepare an individual study and design.
The study comes with no obligation. An engineer replies within 24 hours.